  • online UPS 3C15~20kVA
    Basic Features

    Smaller design

    The application of advanced control technology, greatly improve the power factor, small volume, light weight.

     

    Online maintenance design (optional)

    If you select the maintenance switch, you can safely carry out online maintenance under the condition of continuous load power supply as long as you turn the UPS to the maintenance mode; If you plan for N+1 parallel redundancy, even if the mains power is interrupted during maintenance, your valuable equipment can get uninterrupted high-quality power supply.

     

    Comprehensive functional design

    DC start function enables you to use UPS without mains power supply. The function of timing on/off and remote monitoring can realize the goal of unmanned. The powerful charging function is convenient for you to extend the standby time. The intelligent charging mode extends the battery life and saves

    money. The automatic restart function makes it unnecessary for you to turn on the UPS in person after the standby UPS is turned off. Comprehensive functional design brings more convenience to your work.

     

    Excellent technical indicators

    The input power factor close to 1 greatly reduces the pollution to the municipal power grid, improves the utilization of the grid, and is a real green power source. The ultra wide input voltage range provides the most complete protection for your valuable equipment under various harsh power environments.

    Nearly 93% full load operation efficiency, effectively saving your electricity bill. Strong anti-interference ability, meeting the requirements of IEC61000-4 for electromagnetic interference, can effectively eliminate noise, high voltage and breakthrough on the power grid, and provide a clean power environment for your

    equipment.

     

    Optional lightning protection function

    It can be equipped with Class D lightning arrester with surge and lightning protection design to effectively protect equipment from lightning interference.

     

    High-reliability and parallel capacity expansion technology (optional)

    You only need to consider your actual power needs and plan an appropriate UPS. In the future, if you need corresponding power expansion due to equipment expansion, you only need to purchase the expanded UPS and connect it to the original power system in parallel, which increases the flexibility of planning and greatly reduces the waste of investment. 

     

    N + X parallel redundancy function (optional)

    The N+X parallel redundancy function means that there is one more UPS at any time to guarantee your important equipment. When planning the power supply system, add one more than the rated capacity. In this way, when any UPS in the system fails, the additional UPS will enable the power supply system to continuously provide high-quality power for your important equipment, making the system more reliable. At the same time, the advanced current sharing technology enables each UPS in parallel operation to share the load current equally. While improving the system reliability, It also extends the service life of UPS.

     

    Intelligent power supply monitoring and management software: UPSILON 2000

    Support Microsoft Windows95/98/Me/NT/2000/XP/Linux operating system, applicable to TCP/IP LAN, and support TCP/IP network monitoring UPS; Provide hierarchical directory structure management network UPS; Abnormal event notification; Automatically detect UPS model and communication port; Provide password protection; UPS can be switched on/off regularly; Support UPS timing self-test function; Support graphic real-time display of UPS status; Support network shutdown of servers and workstations; Support closing most applications and saving related documents; Support multi language and English platforms; Support online help function. It has the function of data recording (including mains power, UPS, load, battery) and event log, which is convenient for the system administrator to carry out daily UPS maintenance. 

     

    Complete monitoring and communication function 

    RS-232, intelligent slot (Intelligent Slot) and other monitoring and communication interfaces are provided. Users can realize centralized monitoring and remote monitoring functions through the SNMP network card.

     

    Technical Specifications
     
    Model 31-10K 31-10KS 31-15K 31-15KS 31-20K 31-20KS
    Capacity VA/W 10kVA/9kW 15kVA/13.5kW 20kVA/18kW  
    Topology Double Conversion Online UPS  
    Phase Single Phase Input Single Phase Output  OR
    3 Phases Input Single Phase Output
    AC
    Mains Input
    Wiring Single Phase L/N+PE   OR 3 Phases (L1,L2,L3,N)/N+PE
      Rated Voltage 208/220/230/240VAC
      Voltage Range Line-Neutral  90~300VAC
    Line-Line 150~500VAC
      Frequency Range 40Hz-70Hz
      Input Power Factor ≥0.99
    AC Output Wiring L/N+PE
      Rated Output Voltage 208/220/230/240VAC
      Voltage Regulation ±1%
      Output Frequency 50/60±4Hz(Sync Mode) / 50/60Hz±0.1%(Free Run)
      Waveform Pure Sine Wave
      Distortion
    (THDV%)
    <2%(Linear Load)
        <7%(None-Linear Load)
      Over load capability 10Min@105%~125%Rated Load
    60Sec.@125%~150%Rated Load
    0.5Sec.@>150%Rated Load
    Efficiency Line mode >94%
      Battery Mode >92%
    Battery
    &
    Charge
    Rated Battery Voltage 192VDC
    12Vx16pcs
    192/240VDC External Battery 192VDC
    12Vx32pcs
    192/240VDC External Battery 192VDC
    12Vx32pcs
    192/240VDC External Battery
      Battery Capacity 12V/7AH External Battery Depends 12V/7AH External Battery Depends 12V/9AH External Battery Depends
      Backup Time >10mins
    @half Load
      >10mins
    @half Load
      >10mins
    @half Load
     
      Charging Current standard Model with Internal Battery:10K:2/4A; 15K~20K:4A,
    Long Backup Time Model :4A/8A
      Optional Configuration to Order
    1. Battery Capacity 7AH/9AH
    2. Battery Quantity 32pcs
    Physical Chassis Style  Tower
      Tower Dimension  31-10KS: 190(W)X340(H)x562(D)mm   31-10K: 190(W)X472(H)x586(D)mm
    31-15/20KS: 239(W)X529(H)x581(D)mm  
    31-15/20k: 300(W)X700(H)x698(D)mm
      Weight (kg) 47.8kg 17.0kg 88.7kg 25.6kg 105.2kg 26.1kg
    HMI LCD DISPLAY Input Mains Voltage, Frequency, Load level, Operation Mode, Health Status
      Standards
    Communication Interface
    1RS232 PORT
      Optional Extension Card   2EPO / ROO Port  3Intelligent Slot  4USB Card (not HID)
      5NetWork Card:  Support SNMP/TCP/IP for remote monitoring the UPS via Smart Phone APP, Web page,  PC Monitor Software , Support Server / NAS shutdown
      6CMC MODBUS Card,   7AS400 Relay Card
    Operating Environment
    Endurance
    Temperature range -10~50oC
      Relative Humidity 0-98%Non-condensing
      Acoustics Noise <55dB @ 1 meters

    1. Optional rated capacity (output power) PF = 0.8.

    2. The model with "S" is a extended time model, and the battery should be configured according to the external battery DC voltage according to the battery life time.

    3. Load in high altitude = rated power x reduction coefficient

    Altitude (m)

    1000

    1500

    2000

    2500

    3000

    3500

    4000

    4500

    5000

    Frequency reduction coefficient

    100%

    95%

    91%

    86%

    82%

    78%

    74%

    70%

    67%

     If the UPS is used above 1000m, the decreasing rated output must be used, as shown in the table above.

    * The above parameters may be adjusted and changed, please refer to the physical object.