  • Integrated power supply and distribution UPS (PDM series 15~200kVA)
    Basic Features

    Application area

    Small and medium-sized data center, IT computer room, financial institutions, traffic dispatch center, security monitoring, etc.

     

    Features and advantages

    1. Set power cabinet, modular UPS, output cabinet and intelligent monitoring four functions to realize the integration of multiple cabinets and save space.

    2. 10.1 inch color touch control screen, built-in Chinese / English one-button switching function interface, for UPS, power distribution operation control, operation status view, parameter setting, alarm view and other functions. Easy to quickly view the current device status, and can touch the local control.

    3. Strong access ability, can flexibly expand the moving ring monitoring function. Support intelligent equipment and DI dry contact input equipment connected by RS485 and TCP communication mode, can expand the room access control management, temperature and humidity, fire protection, battery management, precision air conditioning monitoring, SMS alarm and other functions, to achieve multi-effect integration.

    4. Built-in web service, which can be remotely monitored and managed through the browser and APP.

    5. Support custom alarm configuration, alarm support SMS notification (optional 4G version) and email push (need to be connected to the external network).

    6. The data can be uploaded to the centralized management platform through the northbound interface, and the local data can be exported to the U disk.

    7. large capacity storage, with 4G storage capacity, can be expanded through TF card, the maximum support of 128G, historical data can be stored for 1 year, offline real-time storage for 7 days.

    8. Ultra-wide input voltage range of 138 V ~ 485 Vac, 305 ~ 485 Vac, 138 ~ 305 Vac linear decrease, adapted to the harsh power grid.

    9. Full modular design of power module, bypass module and control module.

    10. Each module supports hot plug, which is convenient for users to flexibly configure and invest gradually in, and easy to maintain.

    11. The mains input mode is optional. Dual input is standard equipped with PC class ATS with fire control function, which has fast switching response and ensures the continuity and safety of power supply.

    12. UPS can share the battery pack, and the number of external battery pack segments 30-50 is flexible and adjustable.

     

    Product mix

     

    image.png

     

     

     

    Technical Specifications

    Product model

    MP-90K-PDM - MCCB160

    MP-90K-PDM - ATS160

    MP-120K-PDM - MCCB250

    MP-120K-PDM - ATS250

    MP-150K-PDM - MCCB400

    MP-150K-PDM - ATS400

    MP-180K-PDM - MCCB630

    MP-180K-PDM - ATS630

    Total output capacity of the cabinet

    105kVA

    150kVA

    250kVA

    400kVA

    UPS

    UPS frame capacity

    90kVA/90kW

    120kVA/120kW

    150kVA/150kW

    180kVA/180kW

    Adaptation module specifications

    15 / 20 / 25 / 30 kVA (kW) height: 2U

    Maximum number of modules

    3

    4

    5

    6

    Import

    Enter the system

    Three-phase, four-wire + PE

    Rated input voltage

    380 Vac / 400 Vac / 415 Vac (line voltage)

    Input voltage range

    138 to 485 Vac; 305 to 485 Vac, 138 to 305 Vac.

    Input frequency range

    40Hz 70Hz

    Input power factor

    > 0.99

    Input current harmonic component

    THDi 3% (linear load, highest point reached); THDi 5% (non-linear load, highest point reached).

    Bypass

    Rated AC voltage

    380 Vac / 400 Vac / 415 Vac three-phase four-wire, common mid-line with the rectifier input, to provide a mid-line reference for the output.

    Overload

    <110%,long-time 1="" 5="">150%,1 second

    Rated midline current

    1.7 ×In

    Frequency

    50/60Hz

    Switching period

    ≤2mS

    Bypass voltage range

    Can be set: upper limit: + 5%, + 10%, + 15%, + 20%, + 25%, default is + 15%; lower limit: -20%, -30%, -45%, default is-20%.

    Output

    Output system

    Three-phase four wire + PE (midline with bypass)

    Rated output voltage

    220 Vac / 230 Vac / 240 Vac (phase voltage)

    Stable pressure accuracy

    ± 1% (balanced load)

    Rated output frequency

    50/60Hz

    Output power factor

    1

    Output voltage imbalance degree

    ± 1% (0 to 100% Linear load)

    Inverse overload capacity

    100%~110% load, bypass after 60min; 110% ~ 125% load, 10min bypass; 125% ~ 150% load, 1min bypass; 200ms after 150% and short circuit.

    Emergency Shutdown (EPO)

    Close the output immediately

    Cell

    Supporting battery type

    Standard: Valve-acid battery (VRLA) (optional lithium battery)

    Battery voltage

    ±180 ~ ±300Vdc

    Number of battery parallel groups

    Group 1 ~8

    Battery section number

    30 ~50 (12V battery, default 12V battery 40, battery number double number adjustment)

    Floating charge voltage

    2.25V / cell (with a range: 2.20V / cell ~2.30V / cell)

    Temperature compensation

    -3.0 mV / Cell /  (range: 0~5.0))

    Generalized voltage

    2.35V / cell (available range: 2.30V / cell ~2.40V / cell)

    Final discharging voltage

    1.80V / cell (available range: 1.60V / cell ~1.90V / cell)

    Maximum charging current

    Range: (1 ~15A) * number of modules

    Distributing

    Input mode

    Single-way three-phase & four-wire + PE

    Double-road, three-phase & four-wire + PE

    Single-way three-phase & four-wire + PE

    Double-road, three-phase & four-wire + PE

    Single-way three-phase & four-wire + PE

    Double-road, three-phase & four-wire + PE

    Single-way three-phase & four-wire + PE

    Double-road, three-phase & four-wire + PE

    Input specification

    MCCB160A/3P

    PC grade ATS160A / 4P

    MCCB250A/3P

    PC grade ATS250A / 4P

    MCCB400A/3P

    PC grade ATS400A / 4P

    MCCB630A/3P

    PC grade ATS630A / 4P

    UPS distributing

    Input, bypass, output, maintenance bypass: 100A / 3P * 4, MCCB

    Input, bypass, output, maintenance bypass: 160A / 3P * 4, MCCB

    Input, bypass, output, maintenance bypass: 250A / 3P * 4, MCCB

    Input, output and maintenance bypass: 250A / 3P * 3, MCCB

    Live load

    Air conditioning: 63A / 3P / 4, mains: 10A / 1P / 3.

    IT load

    (32A / 1P * 15 + 63A / 1P * 3) * 2 road, MCB

    (32A / 1P * 21 + 63A / 1P * 3) * 2 road, MCB

    (32A / 1P * 21 + 63A / 1P * 3) * 2 road, MCB

    (40A / 1P * 18 + 63A / 1P * 6) * 2 road, MCB

    Lightning protection

    Class C lightning protection, 20 kA / 4P.

    Supervisory control

    Standard configuration

    Full power parameters and switch status monitoring of main / branch distribution; Monitoring of complete UPS operating parameters and operating parameters of each module unit; Browser Remote access monitoring system, Remote viewing, setting, and control (connected to the external network); Email and wechat alarm, Mobile APP remote monitoring management (connected to external network); Support for the Modbus TCP / SNMP northbound interface; The monitoring content also includes: equipment real-time status query, alarm query, historical data query, system log query, alarm event management, alarm notification mode, user alarm Settings, alarm notification record, alarm linkage record, equipment management, user management, system Settings and other functions;

    Apolegamy

    Air conditioning monitoring, battery management, access control management, local sound and optical alarm, SMS alarm or telephone SMS two-in-one alarm, environmental temperature and humidity monitoring, water leakage detection, smoke detection, rack embedded fire extinguisher, etc.

    System

    System effectiveness

    > 95.5%

    Levels of protection

    IP20

    Communication interface

    Dry contacts, RS485, and SNMP

    Running temperature

    040

    Storage temperature

    -25 70

    Relative humidity

    5 ~ 95% RH (no condensation)

    Above sea level

    0 ~1000m (IEC62040-3 standard above 1000m, up to 4000m)

    Physical characteristics

    Reference weight

    327kg

    332kg

    356kg

    363kg

    397kg

    407kg

    422kg

    430kg

    Dimensions (W * D * H)

    600*1100*2000mm/600*1200*2000mm

    Operative norm

    CE ,EN/IEC 62040-2 ,EN/IEC 62040-1-1 ,YD/T 2165-2017

     

    *The above parameters may be adjusted and changed, please refer to the real object.

    *Comply with international EMC safety regulations.

     

    Product model

    MP-100K-PDM - MCCB250

    MP-100K-PDM - ATS250

    MP-200K-PDM - MCCB630

    MP-200K-PDM - ATS630

    Total output capacity of the cabinet

    150kVA

    400kVA

    UPS

    UPS frame capacity

    100kVA/100kW

    200kVA/200kW

    Adaptation module specifications

    50 kVA (kW) height: 3U

    Maximum number of modules

    2

    4

    Import

    Enter the system

    Three-phase, four-wire + PE

    Rated input voltage

    380 Vac / 400 Vac / 415 Vac (line voltage)

    Input voltage range

    138 - 485 Vac; 305 - 485 Vac,no derating, 138 - 305 Vac linear derating.

    Input frequency range

    40Hz 70Hz

    Input power factor

    > 0.99

    Input current harmonic component

    THDi 3% (linear load, highest point reached); THDi 5% (non-linear load, highest point reached).

    Bypass

    Rated AC voltage

    380 Vac / 400 Vac / 415 Vac three-phase four-wire, common mid-line with the rectifier input, to provide a mid-line reference for the output.

    Overload

    <110%,long-time 1="" 5="">150%,1 second

    Rated midline current

    1.7 ×In

    Frequency

    50/60Hz

    Switching period

    ≤2mS

    Bypass voltage range

    Can be set: upper limit: + 5%, + 10%, + 15%, + 20%, + 25%, default is + 15%; lower limit: -20%, -30%, -45%, default is-20%.

    Output

    Output system

    Three-phase four wire + PE (midline with bypass)

    Rated output voltage

    220 Vac / 230 Vac / 240 Vac (phase voltage)

    Stable pressure accuracy

    ± 1% (balanced load)

    Rated output frequency

    50/60Hz

    Output power factor

    1

    Output voltage imbalance degree

    ± 1% (0 to 100% Linear load)

    Inverse overload capacity

    100%~110% load, bypass after 60min; 110% ~125% load, 10min bypass; 125% ~150% load, 1min bypass; 200ms after 150% and short circuit.

    Emergency Shutdown (EPO)

    Close the output immediately

    Cell

    Supporting battery type

    Standard: Valve-acid battery (VRLA) (optional lithium battery)

    Battery voltage

    ±180 ~ ±300Vdc

    Number of battery parallel groups

    Group 1 ~8

    Battery section number

    30 ~50 (12V battery, default 12V battery 40, battery number double number adjustment)

    Floating charge voltage

    2.25V / cell (with a range: 2.20V / cell ~2.30V / cell)

    Temperature compensation

    -3.0 mV / Cell /  (range: 0~5.0))

    Generalized voltage

    2.35V / cell (available range: 2.30V / cell ~2.40V / cell)

    Final discharging voltage

    1.80V / cell (available range: 1.60V / cell ~1.90V / cell)

    Maximum charging current

    Range: (1 ~20A) * number of modules

    Distributing

    Input mode

    Single-way three-phase & four-wire + PE

    Double-road, three-phase & four-wire + PE

    Single-way three-phase & four-wire + PE

    Double-road, three-phase & four-wire + PE

    Input specification

    MCCB250A/3P

    PC grade ATS250A / 4P

    MCCB630A/3P

    PC grade ATS630A / 4P

    UPS distributing

    Input, bypass, output, maintenance bypass: 160A / 3P * 4, MCCB

    Input:320A/3P*1bypass,output and maintenance bypass: 250A / 3P * 3, MCCB

    Input:320A/3P*1 output and maintenance bypass: 250A / 3P * 2, MCCB

    Live load

    Air conditioning: 63A / 3P / 4, mains: 10A / 1P / 3.

    IT load

    (32A / 1P * 15 + 63A / 1P * 3) * 2 road, MCB

    (40A / 1P * 18 + 63A / 1P * 6) * 2 road, MCB

    Lightning protection

    Class C lightning protection, 20 kA / 4P.

    Supervisory control

    Standard configuration

    Full power parameters and switch status monitoring of main / branch distribution; Monitoring of complete UPS operating parameters and operating parameters of each module unit; Browser Remote access monitoring system, Remote viewing, setting, and control (connected to the external network); Email and wechat alarm, Mobile APP remote monitoring management (connected to external network); Support for the Modbus TCP / SNMP northbound interface; The monitoring content also includes: equipment real-time status query, alarm query, historical data query, system log query, alarm event management, alarm notification mode, user alarm Settings, alarm notification record, alarm linkage record, equipment management, user management, system Settings and other functions;

    Apolegamy

    Air conditioning monitoring, battery management, access control management, local sound and optical alarm, SMS alarm or telephone SMS two-in-one alarm, environmental temperature and humidity monitoring, water leakage detection, smoke detection, rack embedded fire extinguisher, etc.

    System

    System effectiveness

    > 96%

    Levels of protection

    IP20

    Communication interface

    Dry contacts, RS485, and SNMP

    Running temperature

    040

    Storage temperature

    -25 70

    Relative humidity

    5 ~ 95% RH (no condensation)

    Above sea level

    0 ~1000m (IEC62040-3 standard above 1000m, up to 4000m)

    Physical characteristics

    Reference weight

    330kg

    335kg

    431kg

    435kg

    Dimensions (W * D * H)

    600*1100*2000mm/600*1200*2000mm

    Operative norm

    CE ,EN/IEC 62040-2 ,EN/IEC 62040-1-1 ,YD/T 2165-2017

                         

    *The above parameters may be adjusted and changed, please refer to the real object.

    *Comply with international EMC safety regulations.

     