  • Fault tolerant N+X modular ups MP series20~1200kVA (single set)
    Basic Features


    1755691610692954.png

    This product is applicable to a wide range of computer equipment , communication systems and automatic equipment.

    High reliability design

    Ultra wide input voltage range: 138 ~485Vac ( phase voltage: 80 ~280Vac) , no derating for use above 305Vac .

    Energy saving , green and environmental protection

    High input PF value , up to 0 .99. The three-level topology is adopted , and the overall efficiency is up to 96 .5% .

    Parallel redundancy function

    Direct parallel connection , 6 sets can be connected in parallel , and the parallel connection can share the battery pack.

    Flexible battery configuration scheme

    The number of battery cells can be set from 30 to 50. The single machine has large capacity charging power to meet the backup demand of long time delay.

    Super load capacity

    The output power factor is 1/0.9 . It can carry 100% unbalanced load. It has strong load adaptability and can carry pure inductive load and capacitive load close to full load.

    Compatible with generator operation

    The Power Walk In function can reduce the impact current of system startup and reduce the demand of parallel system for generator capacity.

    LBS synchronization function

    LBS synchronization function is provided to realize synchronization of two independent UPS systems and improve system reliability.

    Intelligent management function

    Support RS485 , SNMP , dry contact and CAN interface .

     

    Technical Specifications

    Model ( max . capacity)

    MP200kVA/ MP300kVA/ MP400kVA/ MP500kVA/ MP600kVA/ MP800kVA/MP1200kVA

    Capacity

    UPS cabinet

    80K~200K-20、90K~300K-30、120K~400K-40、200K~800K-50(60)、600K-100、1200K-100

    Modular

    20kVA/30kVA/40kVA/50kVA/60kVA/100kVA

    Main circuit input

     

    Power supply system

    Three phase four wire+grounding

    Rated voltage

    380/400V/415VAC

    Voltage range

    138~485 , 305~485Vac (no derating) , 138~305 Vac (linear derating)

    Frequency range

    40~70Hz

    Power factor

    >0 .99

    Input current harmonic

    <3% ( 100% linear load)

    Bypass input

     

    Input voltage

    380/400V/415Vac

    Bypass range

    Upper limit of bypass protection voltage:+25% (optional+5% , +10% , +20%)

    Lower limit of bypass protection voltage: -45% (optional -20% , -30%)

    Power supply system

    Three phase five wire

    Bypass synchronous tracking range

    50/60Hz±10%

    Power Walking In

    Support

    Bypass back filling

    Support

    Generator connection

    Support

    Output

     

    Rated voltage

    380/400V/415VAC ±1%

    Power factor

    1 .0/ 0 .9

    Voltage accuracy

    ± 1 %

    Output frequency

    Mains mode

    Synchronize with input; When the mains frequency exceeds the maximum ± 10% (± 1 % , ± 2 % , ± 4 % , ± 5 % can be set) , output frequency 50/60 (± 0 .2 %) Hz .

    Battery mode

    50/60(±0 . 1 %)Hz

    Load peak ratio

    3:01

    Transfer time

    Mains mode to bypass mode: 0ms (tracking) ; mains mode to battery mode: 0ms

    Overload capacity

    Load ≤ 110%, maintain for 60min, ≤ 125%, maintain for 10min, ≤ 150%, maintain for 1min

    Output voltage distortion

    ≤ 2 % ( linear load)

    ≤ 4 % ( non-linear load)

    Efficiency

     

    Normal mode

    ≥96 .5 %

    Communication interface

     

    UPS cabinet

    RS232 , RS485 , 2 intelligent slots , dry contact

    Battery

     

    Battery voltage

    ±180~ ±300Vdc (30~50 sections optional)

    Work environment

     

    working temperature

    -10 ~45

    relative humidity

    0~95% non condensing

    Storage temperature

    -20 ~65

    Altitude

    1500m

    Noise ( Db)

    70 ( 1 m away)

    Physical characteristics

    20/30/40kVA 

            3 module cabinet

    20/30/40kVA 

          5/6 module cabinet

    20/30/40kVA 

           10 module cabinet

    50/60kVA 4/6/8/10/12 module 

                            cabinet

    100kVA 6/12 module 

                     cabinet

    Dimension
    W×D×H(mm)

    System cabinet

    600 × 850 × 1400

    600 × 850 × 1400

    600 × 850 ×2000

    600 × 850 ×2000/1200×850×2000

             800 ×1000×2000/           2200×1000×2000

    Modular

    440 × 580 × 86

    440 × 620 × 130

    440 × 750 × 130

    Weight (Kg)

    System cabinet

    142

    142

    245

    178/240/411/435/510

    440/780

    Modular

    18.5/21/22

    33/33.2

    49

    Executive standards

     

    Executive standards

    CE , EN/ IEC 62040-2 , EN/ IEC 62040-1-1 , YD/T2165-2017

    *The above parameters may be adjusted and changed , please refer to the real object.   

    *Comply with international EMC safety regulations .

     

Some of the images and text on this site are from the internet. If there are any copyright issues, please notify us so we can handle them.